Types of seasonal thermal storage systemSeasonal (or "annualized") thermal storage can be divided into three broad categories:
In all cases, very effective above-ground insulation / superinsulation of the building structure is required to minimize heat-loss from the building, and hence the amount of heat that needs to be stored and used for space heating. Despite the differences in design that they involve, low-temperature systems tend to offer simple and relatively inexpensive implementations which are less vulnerable to equipment failure. They do, however, require the site of the building to be clear of the water table, bedrock and existing buildings, and are limited to temperate (or warmer) climate zones and to space heating only. High-temperature systems share the same vulnerabilities as conventional space and water heating systems due to their 'active' mechanical and electrical components, as well as their advantage of enabling greater control. They can also be employed in colder climates. Low-temperature seasonal heat storesOne of the original motivations of early man's movement into caves was probably the ability of the earth to naturally even out variations in temperature. At depths of about 20 feet (6m) temperature is naturally “annualised” at a stable year-round temperature. With the development of modern passive solar building design, during the 1970s and 1980s a number of techniques were developed in the US that enabled thermally and moisture-protected soil to be used as an effective seasonal storage medium for space heating, with direct conduction as the heat return method. Two basic techniques can be employed:
These concepts are compared in greater detail at: www.greenershelter.org. Warm-temperature seasonal heat storesWarm-temperature heat stores are a development of low-temperature stores in that solar collectors are used to capture surplus heat in summer and actively raise the temperature of thermal banks of soil so that heat can be extracted more easily (and more cheaply) in winter. Interseasonal Heat Transfer3 uses water circulating in pipes embedded in tarmac solar collectors to transfer heat to Thermal Banks4 beneath the insulated foundation of buildings. A ground source heat pump is used in winter to extract the warmth from the Thermal Bank to provide space heating via underfloor heating. A high Coefficient of Performance is obtained because the heat pump starts with a warm temperature from the thermal store. High-temperature seasonal thermal storesHigh-temperature seasonal thermal stores are found on a variety of scales, from those installed in individual houses to those serving neighbourhoods via district heating. Individual structuresAlthough the use of high-temperature seasonal thermal stores within individual buildings dates back to at least 1939 (MIT Solar House #1), the United States, Switzerland and Germany have all been notable pioneers in this field. Perhaps the best known international example of this active approach is the experimental “Jenni-Haus” built in 1989 in Oberburg, Switzerland. This has 3 tanks storing a total of 118m³ (4,100 cubic feet) 5 providing far more heat than is required to heat the building. The more recent “Zero Heating Energy House”, completed in 1997 in Berlin as part of the IEA Task 13 low energy housing demonstration project, stores water at temperatures up to 90 °C (195 °F) inside a 20m³ (700 cubic feet) tank in the basement 6, and is now one of a growing number of similar properties. NeighbourhoodsAt the neighbourhood level, the Wiggenhausen-Süd solar development at Friedrichshafen has received international attention. This features a 12,000 m³ (424,000 cubic feet) reinforced concrete thermal store linked to 4,300m² (46,000 square feet) of solar collectors, which will supply the 570 houses with around 50% of their heating and hot water 7. A different approach is illustrated by the Drake Landing Solar Community development in Okotoks, Alberta. Here the store is created from the ground itself, with solar heated water pumped into a Borehole Thermal Energy Storage (BTES) system. This consists of 144 boreholes, each 37m (121 ft) deep, which heat the ground to a maximum of around 90 °C (195 °F) 8. GreenhousesThermal storage (sometimes referred to as heat and cold storage) is also used extensively for applications as the heating of greenhouses.9 In summer, the greenhouse is cooled with ground water, pumped from an aquifer, which is the cold source. This heats the water, which is then stored by the system in a warm source. In winter, the warm water is pumped up to supply heat. The now cooled water is returned to the cold source. 910111213 The combination of cold and heat storage with heat pumps has an additional benefit for greenhouses, as it may be combined with humidification. In the (closed circuit) system, the hot water is stored in one aquifer, while the cold water is stored in another. The water is used to heat or cool the air, which is moved by fans.14 Such a system can be completely automated. 15 See also
References
External links
| |