History of cellulose insulationCellulose is the oldest building insulation materialcitation needed. Many types of cellulosic materials have been used, including newspaper, cardboard, cotton, straw, sawdust, hemp and corncob. Monticello was insulated with a form of cellulose. Modern cellulose insulation, made with recycled newspaper using grinding and dust removing machines and adding a fire retardant, began in the 1950s and came into general use in the US during the 1970s. ProductsFour major types of loose-fill cellulose products have been developed under a variety of brand names. These are generally characterized as dry cellulose, spray applied cellulose, stabilized cellulose and low dust cellulose. These types are used in different parts of a building and for different reasons. Dry Cellulose (Loose Fill)Dry cellulose is used in retrofitting old homes by blowing the cellulose into holes drilled into the tops of the walls. It can also be blown into a new wall construction by using temporary retainers or netting that is clamped in place then removed once the cellulose has reached the appropriate density. This form of application does settle as much as 20% but the stated R-value of the cellulose is accurate after settling occurs. In addition, a dense-pack option can be used to reduce settling and further minimize air gaps. Dense-pack places pressure on the cavity, and should be done by an experienced installer. Spray Applied Cellulose (Wet-Spray)Spray applied cellulose is used for applying cellulose to new wall construction. The only difference is the addition of water to the cellulose while spraying. In some cases the insulation might also mix in a very small percentage of adhesive or activate a dry adhesive present in the cellulose. Wet-spray allows application without the need for a temporary retainer. In addition, wet-spray allows for an even better seal of the insulated cavity against air infiltration and eliminates settling problems. Wet-spray installation requires that the wall be allowed to dry for a minimum of 24 hours (or until maximum of 25% moisture is reached) before being covered. [2] Stabilized CelluloseStabilized cellulose is used most often in attic/roof insulation. It is applied with a very small amount of water to activate an adhesive of some kind. This reduces settling and decreases the amount of cellulose needed. This can prove advantageous at reducing the overall weight of the product on the ceiling drywall helping prevent possible sag. This application is ideal for sloped roofs and has been approved for 5:12 (41.66%) slopes. [3] Low-Dust CelluloseThe last major type of cellulose insulation on the market is low dust variety. Nuisance levels of dust are created during application of most types of dry insulation causing the need for simple dust masks to be worn during installation. This kind of cellulose has a small percentage of oil or similar dust dampener added. This may also be appropriate to homes were people are sensitive to newsprint or paper dust (though new dust will not be created after installation). AdvantagesThermal PerformanceThe thermal performance of loose filled cellulose compares favorably to other types of insulation. The thermal conductivity of loose-fill cellulose is approximately 40 mW/(K*m) (an R-value of 3.8 per inch) which is about the same as or slightly better than glass wool or rock wool. This doesn’t represent the whole picture of thermal performance. Other important aspects are how well the building envelope is sealed from air infiltration, convective airflows, and thermal bridging. Long-Term Cost SavingsCellulose's insulation qualities "can save homeowners 20 to 50 percent on their utility bills".[4] Sound InsulationNoise reduction is achieved in three ways with cellulose. The first is that cellulose completely fills cavities leaving few air pockets for sound to travel in. The second is the cellulose materials ability to trap air. The significant difference between noise reduction with cellulose and fiberglass is its density. Cellulose is approximately three times denser then fiberglass. This helps deaden the sound through walls and between floor levels. Several installation options allow walls to have a Sound Transmission Class (STC) of 50 or greater.[5] As a comparison, walls with fiberglass batts have an STC of 36-39, depending on stud and screw spacing. Mold and Pest ControlThe borates in cellulose insulation provide superior control against mold, insects, and pests such as rodents. Installations have shown that even several months of water-saturation and improper installation did not result in mold. [6] Fire RetardationThe borate treatment also provides cellulose with the highest (Class I) fire safety rating. This is an advantage over foams and fiberglass. In addition, fire will not cause toxic fumes. Vapor BarrierA vapor barrier may not be needed with cellulose insulation. For example, recent studies have shown that air movement is the primary method by which excessive moisture can accumulate in mild marine climate such as Portland, OR, USA. [7] An insulation that fills the wall cavity completely (such as cellulose or foam) can help prevent moisture problems. Recommendations against using vapor barriers with cellulose insulation are supported by studies, even though they classify cellulose as vapor permeable.[8] [9] In addition, cellulose acts to distribute moisture throughout the cavity, preventing the buildup of moisture in one area and helping to dry the moisture more quickly. Cellulose manufacturers do not recommend the installation of a vapor barrier with cellulose. [10] Most city codes will require a vapor barrier for any external wall. Most US cities will consider an appeal of the requirement if proper reasoning is provided. In March 2008 The US city of Portland, Oregon, approved an appeal to waive the requirement for a vapor barrier/retarder when using cellulose insulation. The appeal can be viewed in the Portland Bureau of Development Services search form by searching for appeal ID 4996. Fundamental to any appeal is mentioning that recent studies show air movement is the primary problem for vapor, that cellulose is an effective barrier to air movement, and that cellulose acts to diffuse vapor. DisadvantagesCellulose has few disadvantages. As compared to other insulation options, the R-Value of 3.6 to 3.8 is very good but not the best (though it competes well in cost per R-Value). Spray foam has many of the same benefits as wet-spray cellulose (such as sealing the cavity), while having an advantage in R-Value and rigidity (however, spray foam has undesirable environmental qualities). Installation Expertise and Building CodesIn some areas it can be difficult to locate installers that are experienced with cellulose. An experienced installer understands how to correctly dense-pack loose fill dry cellulose, how to best apply stabilized (partly-wet) cellulose on sloped surfaces, and the proper time required for wet-spray cellulose to dry. As with other non-batt insulation, city and regional/state building codes may not be updated for cellulose insulation. Homeowners should call the city to verify that the insulation will be approved, and it may be necessary to provide product specifications to the city. This is not difficult, and the installer and the manufacturer should both be willing to handle this process, saving the homeowner any true effort. Most building codes require a vapor barrier, and it can be hard to convince some cities that one is not required for cellulose. In this case, an appeal (usually a quick process) may be necessary. Otherwise, vapor barriers can be installed. Options for a vapor barrier include plastic sheeting (fairly low environmental footprint due to the thin layer needed) or PVA paint (contains toxins and other qualities undesirable from an environmental standpoint). Wet-Spray Drying TimeWet-spray provides the advantage of a better sealing of the insulated cavity and superior rigidity. However, the moisture from a wet-spray insulation requires a longer drying time before the drywall/sheet-rock is applied to a newly insulated wall. This drying time is usually reduced by the use of large space heaters that are run for a few days to weeks, depending on ambient humidity. The installer should use a moisture meter to verify acceptable in-wall moisture levels before any drywall is applied. From an environmental and energy efficiency perspective, wet-spray is well worth the extra heating and time. This extra timing needs to be considered as part of the building schedule for new or remodel projects. Termite InfestationOne drawback to cellulose insulation may be the attractiveness of the primary ingredient to insectscitation needed. Subterranean Termites and Drywood Termites thrive on cellulose. The insulation, especially if used on lower floors acts as an attractant to Termites. Termites can detect simple cellulose such as cellulose insulation, from hundreds of feet up in a high floorcitation needed. Their preferred food source is cellulose with the least resistance to consumption such as papercitation needed. Insulated areas should be checked regularly for signs of the inevitablecitation needed infestation for mud tunnels behind walls and between rafters. However, almost all present-day cellulose insulation contains a borate treatment. The borate will not attract termites or other insects and has been shown to not be a suitable food source for termites.[11] Sustainable and Environmentally Preferable PropertiesCellulose insulation is growing in popularity, in part due to being one of the most environmentally preferable insulation types available. Recycled ContentCellulose is composed of 75-85% recycled paper fiber, usually post-consumer waste newsprint. The other 15% is a fire retardant such as boric acid or ammonium sulphate. Cellulose has the highest recycled content of any insulation available. By example, fiberglass has a maximum amount of 30% recycled content. Low-Toxicity and Environmental Impact of Raw MaterialsThe non-recycled components of cellulose insulation are still environmentally preferable to the raw materials of most other insulation types, which are often petrochemical-based (this includes foam and fiberglass). Unlike foam insulations, many of which use HFC or HCFC blowing agents which have global warming potential hundred or thousands of times higher than that of carbon dioxide, cellulose does not produce significant gaseous emissions. Unlike fiberglass, cellulose does not use formaldehyde-based glues, which present a continuing hazard after installation due to off-gassing of formaldehyde. Cellulose has great advantages for industrial health and worker safety. Toxicity of the raw materials of most insulation types is typically highest during manufacture or installation. Neither is an issue with cellulose. The sole hazard for cellulose is categorization by OSHA as a dust nuisance, requiring a simple dust mask during installation. This compares very favorably to the potential NIOSH cancer risk of fiberglass. Embodied EnergyThe embodied energy of cellulose compared to all other insulation is by far the lowest. It requires 20 to 40 times as much energy to produce furnace-made insulation materials compared to cellulose. Cellulose is made by electrically powered machines while mineral insulation is made in furnaces. Cellulose is also made with locally available materials other than the fire retardant, while mineral insulation factories have to ship materials and products over greater distances. Cellulose insulation does use borates, which are mined in California and Turkey. While small quantities are used, this is a limited resource.[12] Borax mining employs one of the cleanest mining techniques available. [13]. From a mining and natural resource perspective, cellulose is preferable to foam and fiberglass insulation. Insulation is GreenAll insulation helps make buildings more energy efficient. Using cellulose insulation can contribute to obtaining LEED credits in the US Green Building Council certification program. It can earn credit in two categories: the energy and atmosphere energy performance category and the materials and resources recycled content category. Product SafetyCellulose insulation can be very dusty during insulation and it is recommended that a standard dust mask be worn while working. The fire retardant boric acid is about as dangerous as table salt. There is slight concern over the off gassing of ink from the newspapers but the material is sealed behind walls, and no studies have shown this as an issue. External linksGreenFiber Cocoon Insulation, including links to finding an installer. Bob Villa - Beach House Cellulose Installation Video This Old House - Retrofitting Cellulose Insulation video Is a Vapor Barrier Needed for a Cellulose Insulated Home? CIMA Technical Bulletin #2: Standard practice for installing cellulose building insulation References
| |